parameter values can be changed automatically with the scripting window. It is started with the
button from the parameter editor.

The script is written into a textfile, which is generated by an arbitrary editor. The textfile must be in csv-format with the following layout:
The script contains 5 columns, which are separated by a semicolon.
1. Time in seconds
2. value of the parameter without unit.
3. device name. It must be either Short Name (Parameter 0005) or the address for example "UDP: 10.49.1.42:2904".
4. parameter id
5. sub id
An example looks as following:
5;0;CAN-IO;3104;0
10;1;CAN-IO;3104;0
In this example the parameter 3104 is set to 0 after 5 seconds past pressing the start button. 5 seconds later (10 seconds after start) the parameter is set to 1.
If the button loop is pressed, the script restarts after the last line.